This three-day event brings together 200–250 industry, academic, and government experts to discuss the latest advances in post‑combustion CO₂ capture technologies, including pilot plants, demonstrations, and operational CCS projects.

The start-up went very smoothly in 2019, even when the feed flowrate fluctuated between 65% to 105% of the design flowrate. Axens process design is quite robust to face possible start-up and operating troubles. After a week of operation the temperatures were adjusted as per design to 113°C and 120°C for First and Second Reactors respectively. The isomerate RON was above 88, up to 89.2 sometimes, according to our laboratory.
HCl Absorber efficiency was high. C2Cl4 injection was gradually decreased to minimum recommended ratio of Cl/feed but HCl concentration detected in Stabilizer off-gas was still above 5000 ppm.
Currently we are still very satisfied with Axens ISOM technology and ATIS-2L catalyst. Thanks to the HCl recovery innovation we save 75% of chemicals, and earn 1% isomerate yield more.